Table 5A — Accessory Electric Heater Data (60 Hz)
UNIT
40RMQ
HEATER
PART NO.
V-PH-Hz NOMINAL kW
HEATER
AMPS
MCA* MOCP*
008
CAELHEAT001A00 240-3-60
5
12.0 25.6 30
CAELHEAT002A00 480-3-60 6.0 12.3 15
CAELHEAT003A00 575-3-60 5.0 11.9 15
CAELHEAT004A00 240-3-60
10
24.1 40.7 50
CAELHEAT005A00 480-3-60 12.0 19.8 25
CAELHEAT006A00 575-3-60 10.0 18.1 25
CAELHEAT007A00 240-3-60
15
36.0 55.7 80
CAELHEAT008A00 480-3-60 18.0 27.4 40
CAELHEAT009A00 575-3-60 15.1 24.4 35
CAELHEAT010A00 240-3-60
25
60.1 85.8 125
CAELHEAT011A00 480-3-60 30.1 42.4 60
CAELHEAT012A00 575-3-60 25.1 67.0 50
CAELHEAT013A00 240-3-60
35
84.0 115.8 175
CAELHEAT014A00 480-3-60 42.1 57.4 80
CAELHEAT015A00 575-3-60 35.1 49.5 70
LEGEND
MCA Minimum Circuit Amps
MOCP Maximum Overcurrent Protection (Amps)
*Sizes shown are for single-point connection of electric heat acces-
sory and air handler.
NOTES:
1. MCA and MOCP values apply to both standard and alternate factory-
supplied motors.
2. Electrical resistance heaters are rated at 240 v, 480 v, or 575 v. To
determine heater capacity (kW) at unit nameplate voltage, multi-
ply 240-v, 480-v, or 575-v capacity by multipliers found in table
below.
HEATER RATING
VOLTAGE
ACTUAL HEATER VOLTAGE
200 208 230 240 400 440 460 480 550 575 600
240 .694 .751 .918 1 ———— —
480 .694 .840 .918 1
575 .915 1 1.089
NOTE: The following equation converts kW of heat energy to Btuh:
kW x 3.412 = Btuh.
Table 5B — Accessory Electric Heater Data (50 Hz)
UNIT
40RMQ
HEATER
PART NO.
V-PH-Hz NOMINAL kW
HEATER
AMPS
MCA* MOCP*
008
CAELHEAT002A00 400-3-50 3.47 5.0 11.1 15
CAELHEAT001A00 230-3-50 4.59 11.5 25.0 30
CAELHEAT005A00 400-3-50 6.94 10.0 17.3 25
CAELHEAT004A00 230-3-50 9.18 23.1 39.5 50
CAELHEAT008A00 400-3-50 10.42 15.0 23.6 30
CAELHEAT007A00 230-3-50 13.78 34.6 53.9 80
CAELHEAT011A00 400-3-50 17.36 25.1 36.2 50
CAELHEAT010A00 230-3-50 22.96 57.6 82.6 110
CAELHEAT014A00 400-3-50 24.31 35.1 48.7 70
CAELHEAT013A00 230-3-50 32.14 80.7 111.5 175
CAELHEAT017A00 400-3-50 6.94 10.0 23.0 30
CAELHEAT016A00 230-3-50 9.18 23.1 39.5 50
CAELHEAT020A00 400-3-50 13.89 20.0 35.5 50
CAELHEAT019A00 230-3-50 18.37 46.1 79.9 110
CAELHEAT023A00 400-3-50 20.83 30.1 48.1 70
CAELHEAT022A00 230-3-50 27.55 69.2 108.7 150
LEGEND
MCA Minimum Circuit Amps
MOCP Maximum Overcurrent Protection (Amps)
*Sizes shown are for single-point connection of electric heat acces-
sory and air handler.
NOTES:
1. MCA and MOCP values apply to both standard and alternate factory-
supplied motors.
2. Electrical resistance heaters are rated at 230 v or 400 v. To de-
termine heater capacity (kW) at unit nameplate voltage, multiply
230-v or 400-v capacity by multipliers found in table below.
HEATER RATING
VOLTAGE
ACTUAL HEATER VOLTAGE
220 230 240 380 400 415
230 .915 1.0 1.084
400 0.903 1.0 1.076
898 8