Cannon CANTFS-03-LP Gas Heater User Manual


 
5
7. Do not spray aerosols in the vicinity of this appliance while it is in
operation.
Do not place articles on or against this appliance.
Do not use or store flammable materials near this appliance.
8. This heater is not intended for use in a marine environment.
9. If removed, the glass window must be put back onto the unit prior to
operating the heater.
10. Installation and repairs should be performed by a licensed service
person only, refer to page 21 for service number.
11. The appliance should be inspected prior to use, with regular inspec-
tions (annually) to be made by a licensed service person. It is important
that circulating air passageways of the appliance be kept clean, dirt
and lint free, for a safe and efficient operation of the heater.
12. On first lighting your heater a smell may occur due to its new condi-
tion. This is quite normal and will disappear after a few hours use at
the maximum control position.
13. Testing the effectiveness of the flue.
Before testing the flue, confirm air vents are unobstructed. If an exhaust
fan or other heating appliances are present switch them on. This is to
test that there is no interaction between the Cannon heater and other
appliances.
Refer AS5601.
For ‘air movement not to affect appliance’ see clause 5.3.1.
For ‘air supply to appliance’ see clause 5.4.1.
For ‘ventilation requirements’ see clause 5.4.3.
Important:
WHEN THE HEATER IS OPERATING THE GLASS FRONT IS HOT. A safety
guard conforming to Australian Standards requirements is available for this
heater. It is an optional extra, which may be fitted to the heater to reduce
the risk of fire or injury from burns. Its fitting is recommended when there are
children present. For permanent protection of young children or the infirm,
an optional mesh guard is recommended. Call your retailer or CANNON
distributor for further details.
Standards
This appliance meets the following standards:
Standards Australia: AS 3100
AS 5601
AS 4553/AG 103
20
Service instructions
General
1. Service work to be carried out by a licensed service person only.
2. Unplug from wall socket.
3. Always shut off the gas supply and ensure that the heater is cool before
commencing any service operations.
4. Always check for gas soundness after servicing.
Access to components
Remove the pedestal front by unscrewing 4
screws. Refer figure 31.
To replace the primary glass
Follow the steps 8&9 of installation instructions.
Refit glass and replace in reverse order.
To replace the gas control
1. Disconnect the gas regulator connector from
the electronic module.
2. Undo the inlet and outlet compression nuts.
3. Unscrew the four M3 retaining screws adja-
cent to the gas inlet at the rear of the appli-
ance, releasing the control.
4. Replace in reverse order.
To replace the fan
1. Disconnect the fan from the fan plug.
2. Undo the two M5 wing nuts fixing the fan to the burner chamber under-
side.
3. Replace in reverse order.
To replace the electronic controller
1. Remove two screws from controller front.
2. Disconnect the plug.
3. Replace in the reverse order.
To remove the burner and electrodes
1. Follow steps 8 & 9 of the installation instructions.
2. Remove the logs from the burner chamber.
3. Remove the burner chamber front (4 screws).
4. Disconnect the nut from the burner manifold.
5. Remove the electrode connections from the spark module.
6. Remove burner fixing brackets (2) from RH & LH sides of the burner. Lift
the burner assembly upwards and carefully remove from the burner
chamber.
7. Replace in reverse order.
31