Cannon CANTFS-03-LP Gas Heater User Manual


 
10
Overall dimensions: Refer fig. 8.
1. This appliance is to be installed by a licensed service person only.
2. This appliance shall be installed in accordance with the manufacturer’s
installation instructions, local gas fitting regulations, municipal building
codes, electrical wiring regulations, and AS5601 the Australian Stand-
ard for gas installations. Refer also AS5601 for gas pipe sizing tables.
THIS HEATER IS NOT INTENDED FOR FIRE PLACE INSERT.
Clearances
3. Ensure the minimum clearances to combustible construction are main-
tained during installation, including adequate space for the proper op-
eration and servicing of the heater.
For clearances to curtains and furnishings refer to warning 3 & 4 on
page 4.
For minimum clearances refer fig 9 and 10.
4. Remove the carton from the heater and lift from pallet.
Check that the heater is suitable for the gas available. Refer to the data
label located on the fan chamber base, rear of pedestal front.
(Please dispose of packaging appropriately, keep away from children).
5. Prepare electrical and gas connections, a 10 Amp wall socket needs
to be located within 1.5m of the heater.
6. Fit rear spacers as per figure 10.
Installation
7. Place heater in position. (Check flue and gas connection positions.
Refer to gas connection instructions on page 11 and flue installation
instructions on pages 16 & 17, 18 & 19).
8. Remove the front glass surround by holding it firmly on either side and
pulling it towards yourself. Refer figure 11.
9. Remove the inner glass. Slacken off screws in top clamp and remove
side clamps. Refer figure 12.
10
Installation instructions
9
15
Installation tips
Make sure that the heater is fully commissioned and be certain to test
the integrity of the flue operation, taking into account any influences
created by range-hoods, exhaust fans, central heating,etc.
To avoid any unnecessary delays and inconveniences to your cus-
tomer, please contact our Technical Services Department on
1300 727 421 if the installation is unusual or you have any concerns
with the installation and/or heater operation before the installation
commences.
Any service request resulting from incorrect installations are not cov-
ered by our warranty conditions and these will result in charges,usually
to the end user, so please be sure that the installation and commission-
ing has been satisfactorily carried out before calling for any warranty
service.
Please ensure that the end user is fully instructed on how to operate the
heater.