New Buck Corporation 74 Indoor Fireplace User Manual


 
FINAL CHECK
1. Recheck the specified clearances.
2. Remove all foreign material from the firebox area.
3. Open the primary air draft.
4. Plug the power cord into a 115V AC outlet when using with optional motor. Do no run
power cord under unit or in high traffic areas.
5. Place crumpled pieces of newspaper in the stove. Light it and close the door. Ensure that
the stove draws properly through the primary draft.
6. Check for smoke leaks around the door.
7. Open the door and check for smoke escaping from the front of the stove. Smoking usually
indicates a defective or poorly positioned chimney. Some chimneys with a marginal draft
can be preheated by lighting newspaper and holding it near the open damper with a poker or
fire tong. Once the chimney heats up, a proper draft can usually be obtained.
If a thorough review of the Troubleshooting Guide in the rear of the manual does not reveal
the problem, contact your dealer for assistance.
CAUTION
THE UNIT IS PAINTED WITH A SPECIALLY FORMULATED
HIGH TEMPERATURE PAINT THAT CURES DURING THE FIRST TWO OR
THREE FIRINGS. YOU MAY NOTICE A SLIGHT SMOKING EFFECT AND AN
ODOR OF BURNING PAINT WHEN YOU BUILD THE FIRST FIRES. THIS IS
NORMAL AND IS NOT A CAUSE FOR ALARM. IN SOME CASES, THESE FUMES
WILL ACTIVATE A SMOKE ALARM. OPENING A WINDOW NEAR THE UNIT
WILL ALLOW THESE FUMES TO ESCAPE. DO NOT BUILD A LARGE ROARING
FIRE UNTIL THIS CURING PROCESS IS COMPLETE OR THE HEATER FINISH
MAY BE DAMAGED.
29