New Buck Corporation 94NC Stove User Manual


 
FINAL CHECK
1. Recheck specified clearances.
2. Remove all foreign material from firebox area.
3. Open primary air control. Primary Air Controls: The primary air intake control is located
at right bottom side of hearth. It is operated by moving the handle out to open (to allow
air into the firebox) or in (to control or close off) air into the firebox.
4. Plug power cord into a 115V AC outlet when to see if motor and blower works. “Do not
run power cord under unit or in high traffic areas”.
5. Place crumpled pieces of newspaper in stove. Light it and close door. Ensure
that stove draws properly through primary draft.
6. Check for smoke leaks around door.
If a thorough review of Troubleshooting Guide in rear of manual does not reveal problem,
contact your dealer for assistance.
CAUTION
Open door and check for smoke escaping from front of the stove. Smoking usually
indicates a defective or poorly positioned chimney. Some chimneys with a marginal draft
can be preheated by lighting newspaper and holding it near open damper with a poker or
fire tong. Once chimney heats up, a proper draft can usually be obtained.
CAUTION
The unit is painted with a specially formulated high temperature paint that cures during
the first two or three firings. You may notice a slight smoking effect and an odor of
burning paint when you build the first fires. This is normal and is not a cause for
alarm. In some cases, these fumes will activate a smoke alarm. Opening a window near
unit will allow these fumes to escape. DO NOT build a large, roaring fire until this curing
is complete or heater finish may be damaged.
Page 18