Bryant PSPHA732 Thermostat User Manual


 
15
HEAT PUMP SYSTEM NEW THERMOSTAT AND TAPE OFF
WITH COMMON TERMINAL CORRESPONDING TERMINALS NOT USED
EGYY2R OW1W2 B CL
AMANA G Y1 RC-RH W1 W2 X1
AMANA PHD-2,-3,-4,or -5 G R W W1 C
ARCO / Friedrich X2 G Y RC W2 C L
ARCO / Snyder General E G Y R O W1 C X
BARD E G Y1 R W2 B X L
BARD, HP, WH, MHP, HPQ E G Y R W2 W1 X L
BDP / BRYANT E G Y R O W1 C F
BDP E G Y R O W1 (W2) C F
BDP 34427DP97 E G Y R O W1 W2 C L
CARRIER E G Y Y1 R O C L
CARRIER 5Q to W2 G Y, W1 R O W2 C L
CARRIER 50Q, QT382 E G Y R O W2 C L
COLEMAN G Y RED V W2 BLCK
COMFORTMAKER E G Y R O W2 X
COMFORTMAKER H-R8111Y594R1375 E G Y R O W1 C X
FEDDERS K G Y R W1 W2 C L
GE BAY X2 G Y R O W B T
GE BMV 748A G X1 R O W1 W2 B
HEATWAVE SHP251 E G Y R O W1 X
HEIL-QUAKER / Whirpool G Y R O W B
JANITROL / Goodman E G Y R O W2 C
LENNOX TYPICAL HP6 F M V/VR R Y Y X
LENNOX HP8 E F M V/VR R Y Y X
LENNOX HP9, 10 E F M V/VR R Y Y X L
LENNOX HP11 (E) F M M2 VR R Y X
LENNOX HP14 (E) F M M2 V/VR R Y X L
LENOX HP16, 18, 19 E F M V/VR R Y Y X L
MAGIC CHEF PB E G Y1 R W1 W2 C
MAGIC CHEF PE E G Y R O W C
MILLER HEAT / INNERTHERM CORP K G Y R W2 W1 X Z T
PAYNE G Y/Y2 R O/W2 W/W1 C
RHEEM / RUUD E G Y R W2 B X L
RHEEM / RUUD (PCA) E G Y R O W2 W3 X L
SINGER R81111594R1375 E G Y R O W1 C X
SNYDER GENERAL
H-R811/Y594R1375 G Y R O W1 C X
TRANE X2 G Y R O W B F T
TRANE TW X2 G Y R O W B F T
WEATHERKING G W1 R Y1 E C
WESCO E G W1 R Y1 W2 C
WESCO / ADDISON E G W1 R O X
WESTINGHOUSE H50 E G Y R O W X L1
WESTINGHOUSE HE F C V/VR H2 Z X
WESTINGHOUSE 2 SPEED W G Y1 Y2 R O (B) X L
WHITE RODGERS E G Y R O W2 C L
WHITE RODGERS E G Y R O W2 X1
WILLIAMSON E G Y R O W2 W3 X L
WILLIAMSON E G Y R W2 W3 W1 X L
YORK G Y R O W B X
YORK (E) G Y R O W2 (W3) C (L)
YORK EBHP E G R W1 W2 X2
ZONEAIRE E G Y R W2 W3 W1 X L
Important: Use either the B or O terminal, never both.
13. CROSS REFERENCE CHART FOR MULTI-STAGE HEAT PUMPS