Bryant A07048 Thermostat User Manual


 
53
Vacation Setpoints
A special set of temperature and humidity setpoints exist which are active in
vacation mode. They are adjustable by the homeowner, are exclusively for
vacation mode, and are remembered from one vacation selection to the next. See
Ta ble 3 for default values.
Table 3 – Vacation Setpoints Default Values
MODE AUTO
Fan Auto
Heat Setpoint 55
Cool Setpoint 85
Humidify Setpoint 20
Dehumidify Setpoint 60
Vacation Humidification
Normal humidify is available using vacation setpoints. Auto humidification is
available, adjusting its setpoint with outdoor temperature the same as when
occupied. Vacation humidification can be turned off independently of occupied
humidification. While setting the Vacation setpoints, the Vacation humidify
setpoint is accessible by pressing the soft key below the humidify icon when the
box is around the heating setpoint.
Vacation Dehumidification
Normal Dehumidify, Cool to Dehumidify, and Dehumidify OFF are all available
in vacation mode, and selection of one of these can be different from that of
occupied. Vacation dehumidification selection and setpoints are remembered the
next time vacation is used. While setting Vacation setpoints, the Vacation
dehumidify setpoint is accessible by pressing the soft key below the dehumidify
icon when the box is around the cooling setpoint.