Broan ERV90HCT Air Conditioner User Manual


 
1.4.1 HRV UNITS
1. TECHNICAL DATA (CONT’D)
1.4 PERFORMANCE CHARTS
VENTILATION PERFORMANCE
NOTE: A
LL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
.
ENERGY PERFORMANCE
1.4.2 ERV UNITS
VENTILATION PERFORMANCE
NOTE: A
LL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
.
ENERGY PERFORMANCE
- 5 -
SUPPLY
TEMPERATURE
NET AIR FLOW
POWER
CONSUMED
WATTS
SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS
LATENT
RECOVERY/MOISTURE
TRANSFER
°C °F L/S CFM M³/H
HEATING
0 32 23
48 82
68 66 78 0.07
0 32 30
63 108
82 65 76 0.04
0 32 44 93 157 116 59 68 0.04
-25 -13 30 63 108 110 55 81 0.08
COOLING TOTAL RECOVERY EFFICIENCY
35 95 - - - - NOT TESTED
- - - - - -
EXT. STATIC
PRESSURE
NET SUPPLY
AIR FLOW
GROSS AIR FLOW
SUPPLY EXHAUST
PA
IN. W. G.
L/S CFM M³/H L/S CFM M³/H L/S CFM M³/H
25 .1 52 110 187 52 110 187 58 122 205
50 .2 50 106 180 50 106 180 55 116 198
75 .3 48 101 173 48 102 173 53 113 191
100 .4 45 96 162 46 97 166 50 107 180
125 .5 43 92 155 43 92 155 49 103 173
150 .6 41 87 148 41 87 148 45 96 162
175 .7 38 81 138 38 81 137 43 91 155
200 .8 35 75 126 36 76 130 40 85 144
EXT. STATIC
PRESSURE
NET SUPPLY
AIR FLOW
GROSS AIR FLOW
SUPPLY EXHAUST
PA
IN. W. G.
L/S CFM M³/H L/S CFM M³/H L/S CFM M³/H
25 .1 55 116 197 56 119 202 59 125 212
50 .2 53 113 192 55 116 197 57 121 206
75 .3 50 107 182 52 111 189 54 115 195
100 .4 49 104 177 50 107 182 53 112 190
125 .5 46 98 166 48 101 172 50 105 178
150 .6 44 94 160 46 97 165 47 100 170
175 .7 42 88 150 43 91 155 45 95 161
200 .8 39 82 139 40 84 143 42 90 153
SUPPLY
TEMPERATURE
NET AIR FLOW
POWER
CONSUMED
WATTS
SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS
LATENT
RECOVERY/MOISTURE
TRANSFER
°C °F L/S CFM M³/H
HEATING
0 32 13
28 48 73
69
94
0.68
0 32 45
96 163 137
62 74 0.48
-25 -13 25 54 92 102 54 83 0.58
COOLING TOTAL RECOVERY EFFICIENCY
35 95 14 29 49 70 54
- - - - - -