Broan ERV90HCT Air Conditioner User Manual


 
4. CONTROLS (CONT’D)
4.2.1 ELECTRICAL CONNECTION TO VT4W MAIN WALL CONTROL
NO C NC I OC OL Y R G B
B G
OC
MAIN WALL
CO
NTR
O
L
LITE-TOUCH CONSTRUCTO
and
SIMPLE-TOUCH CONSTRUCTO
REAR VIEW
G
B
Y
VE0100A
MAIN WALL
CONTROL VT4W
REAR VIEW
4.2 ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROLS (CONTD)
4.2.2 ELECTRICAL CONNECTION TO OPTIONAL AUXILIARY WALL CONTROLS
NOTE: If an optional auxiliary wall
control is activated and then, the
Humidity Control is being
activated, the Humidity Control
will override the auxiliary wall
control commands.
NO C NC I OC OL Y R G B
20-MINUTED LIGHTED PUSH BUTTON
(5 MAXIMUM)
60-MINUTE
CRANK TIMER
HUMIDITY CONTROL
VE0110A
C
O
M
F
O
R
T
Z
O
N
E
O
F
F
%
R
E
L
A
T
I
V
E
H
U
M
I
D
I
T
Y
70%
60%
50%
40%
30%
25%
20%
HUMIDITY
CONTROL
Once the wall control(s) connections have been made, insert the terminal connector in the bottom of the unit, on the electrical
compartment front face.
4.3 VT4W OPTIONAL MAIN WALL CONTROL OPERATION
WARNING
Risk of electric shock. Before performing
any maintenance or servicing, always
disconnect the unit from its power source.
AVERTISSEMENT
Danger délectrocution. Débranchez
toujours lappareil avant dentreprendre
des travaux dentretien ou de réparation.
CAUTION
Unscrew both screws to open the electrical
compartment. To completely remove, detach
from its retention wire inside.
ATTENTION
Dévisser les deux vis pour ouvrir le compartiment
électrique. Pour retirer complètement, le
détacher de son fil de rétention intérieur.
No light OFF or remote controled
Amber light LOW speed
Green ligh HIGH speed
Blinking light See User Manual
Sans lumière Arrêté ou contrôlé
par contrôle mural
Lumière ambre Basse vitesse
Lumière verte Haute vitesse
Clignotant Voir guide d’utilisation
VD0182
TERMINAL
CONNECTOR
INTERMITTENT
MAX
MIN
VC0070
VT4W
- 18 -
COLOR MODE SUGGESTED USE
GREEN INTERMITTENT SELECT THIS MODE WHEN YOU ARE AWAY FROM THE HOUSE
FOR A FEW DAYS. ALSO, WHEN YOU DEEM THE INSIDE AIR IS
TOO DRY IN HEATING SEASON, OR TOO HUMID DURING
COOLING SEASON. IN THIS MODE, THE UNIT IS OFF FOR
40 MINUTES PER HOUR AND VENTILATES AT MINIMUM SPEED
THE REMAINING
20 MINUTES OF THE HOUR.
YELLOW MIN SPEED
VENTILATION
FOR NORMAL DAILY OPERATION.
RED MAX SPEED
VENTILATION
FOR EXCESS POLLUTANTS AND HUMIDITY
(PARTIES, ODORS, SMOKE, ETC.).