Bradford-White Corp UDS150S*FRN Water Heater User Manual


 
Temperature sensor
Insertion stick
SERVICE PROCEDURE V
Gas Control
Testing, Disassembly & Replacement
GAS CONTROL DISASSEMBLY/REASSEMBLY
Step 12. Remove temperature sensor from insertion stick by pulling apart as illustrated below.
Pull in this direction
Pull in this direction
Step 13. To reassemble Gas Control, follow the previous steps in reverse order. Once Gas Control is reassembled, burner
assembly is reinstalled, and the gas supply line is reconnected, resume water supply to water heater. Be sure tank
is full of water before relighting.
Step 14. To resume operation, follow the instructions located on the lighting instruction label or the lighting instructions
located in the installation and operation manual.
19
The
Bradford
White