Bradford-White Corp UDS150S*FRN Water Heater User Manual


 
SERVICE PROCEDURE V
Gas Control
Testing, Disassembly & Replacement
GAS CONTROL DISASSEMBLY/REASSEMBLY
Step 1. Rotate knob of the Gas Control to the “OFF” position.
Step 2. Turn off gas supply to water heater.
Step 3. Disconnect gas supply line from Gas Control.
Step 4. Disconnect igniter wire.
Step 5. Disconnect main burner feedline, pilot tube and thermopile wires from gas control.
Step 6. Remove Gas Control cover screw.
Rotate knob counter-clockwise to
the “OFF” posistion.
Step 7. Depress both tabs on the top of the Gas Control cover and pull to remove.
Gas Control cover
screw
CAUTION
Use caution not to bend or damage valve body pins
when removing or installing Gas Control cover.
Valve body pins
16
The Bradford White
16