Bradford-White Corp 238-44422-00G Water Heater User Manual


 
17
Maintenance continued-
3. At least once a year, check the combination temperature and pressure
relief valve to insure that the valve has not become encrusted with lime.
Lift the lever at the top of the temperature-pressure relief valve several
times until the valve seats properly without leaking and operates freely.
4. If the combination temperature and pressure relief valve on the appliance
discharges periodically, this may be due to thermal expansion in a closed
water supply system. Contact the water supplier or local plumbing
inspector on how to correct this situation. Do not plug the combination
temperature and pressure relief valve outlet for any reason.
5. Monthly, drain off a gallon of water from the water heater to remove silt
and sediment.
6. A combination sacrificial anode rod/hot water outlet nipple has been
installed to extend tank life. The anode rod should be inspected
periodically (every 2 years) and replaced when necessary to prolong tank
life. Water conditions in your area will influence the time interval for
inspection and replacement of the anode rod. Contact the plumbing
professional who installed the water heater or the manufacturer listed on
the rating plate for anode replacement information. The use of a water
softener may increase the speed of anode consumption. More frequent
inspection of the anode is needed when using softened (or phosphate
treated) water.
WARNING
When lifting lever of temperature-pressure relief valve, hot water will be
released under pressure. Be certain that any released water does not
result in bodily injury or property damage.
WARNING! THIS WATER MAY BE HOT.
CAUTION
FOR YOUR SAFETY, DO NOT ATTEMPT TO REPAIR THERMOSTAT(S),
HEATING ELEMENTS, OR ELECTRICAL WIRING. REFER SUCH
REPAIRS TO A QUALIFIED SERVICE TECHNICIAN.