Bosch Appliances WR430-7K Water Heater User Manual


 
96 720 606 599
Bosch POWER VENTING SYSTEM
VENT INSTALLATION
1. Choose approved terminal location
2. Cut vent terminal opening through outside wall - Refer to installation instructions supplied with termination.
3. Install vent terminal by fastening from outside with 4 screws and caulking around flange edge. Check that
optional flapper moves freely if applicable.
4. Install 4” venting materials and secure all joints with a minimum of four screws for each joint. Please note that
wherever possible use continual lengths of pipe to reduce the number of joints.
5. Seal all positive vent pipe and elbow joints between Bosch unit and vent terminal with high temperature
silicone and/or hi temperature aluminum tape following manufacturer’s instructions (i.e. always push silicone
ahead of nozzle)
ELECTRICAL WIRING:
1. The electrical contact ratings are as follows:
______ 1/10 HP at 120 VAC
______ 3 Amps (full load) at 120 VA
2. Provide switched plug receptacle to accommodate Bosch grounded plug.
3. Make certain the power source is adequate for the fan motor requirements.
Figure 2
REGULATOR VENT
72”
7
2
36”
36”