Bosch Appliances WR430-3K Water Heater User Manual


 
3
DIMENSIONS
Figure 1
Maximum Hydrostatic water pressure - 1.03 MPa (150 p.s.i.)
Maximum recommended working pressure - 0.69 MPa (100 p.s.i.)
Minimum working pressure - 0.09 MPa (13 p.s.i.) no piping attached
Reccomended pressure for showers and domestic, 0.27 MPa (40 p.s.i.)
The high altitude ratings listed are Canadian Gas Association high altitude ratings and are valid only in Canada. In the U.S., the
National Fuel Gas Code, ANSI Z223.1-1988, recommends for high altitude installations above 2,000 feet, that the input rate be
reduced 4% for each 1,000 feet above sea level. - See page 14.
D084_089
EXTERIOR
TERMINATION
Model Type of Gas Altitude Input
Size, mm Qt.
1.20 diam. 18
WR430-3.K.. 0.79 diam. 18
1.20 diam. 18
0.79 diam. 18
Main Burner Orifices
natural gas
propane
0 - 2 000 ft 130 000 Btu/hr (38 kW)
2 - 4 500 ft 116 000 Btu/hr (34 kW)
0 - 2 000 ft 125 000 Btu/hr (36 kW)
2 - 4 500 ft 112 000 Btu/hr (33 kW)