Maintenance and service
31
6.5 Program values
This section describes details on programming the
appliance. For most applications the factory default
values will robust and stable operation. Only adjust the
factory settings if the installation requires changes as
indicated in the appropriate section of this manual.
Refer to chapter 6.6 Control board diagnostics (page
32) regarding how to access these P-modes.
Caution: Misadjusted program
values can lead to appliance
malfunction, errors, and service
calls.
Program Description Factory Default MIN MAX Comment
P1 Maximum Power NG:40, LP:37 21 NG:40, LP:37 see chapter 3.12, page 22.
note: reducing P1 values below
maximum will reduce maximum
power of the appliance.
P2 Minimum Power 6 6 20 see chapter 6.7, page 33
P3 Remote Con-
trols installed
_0 _0 6 see chapter 5.5, page 26
P4 Access to Diag-
nostic Mode
E 0d 10f see chapter 6.6, page 32
P6 Temperature
Unit
°F °F °C
Table 15 Program values, factory default settings and ranges.