Bosch Appliances GWH 2400 ES LP Water Heater User Manual


 
6 720 608 782
20
Installation instructions
3.9 Water connections
B When facing the heater, the ¾” cold connection is on
the bottom right and the hot connection is on the
bottom left. Centrally locating the water heater is
recommended to keep hot water distribution times
even throughout the structure.
Fig. 28
B The use of unions when connecting both water
pipes to the inlet and outlet connections is
required. This will facilitate any necessary
servicing.
B Plastic or PEX type plumbing line materials are not
suitable for connecting directly to the water heater.
B Although water piping throughout the building may
be other than copper, we recommend that copper or
suitably rated stainless steel flex line piping be used
for the water connections for 1.5’ on either side of
the water heater (follow local codes if more
stringent).
B Never sweat any piping directly to or beneath
the water connections, as damage can occur to
the internal water valve from heating of the
pipe.
B Keep water inlet and outlet pipes to no less
than ¾" (19.05mm) diameter to allow the full
flow capacity.
B If the cold and hot connections to the heater are
reversed, the heater will not function. Be certain there
are no loose particles or dirt in the piping. Blow out
or flush the lines before connecting to the water
heater.
B Full port shutoff valves should be installed on both
the cold water supply and hot water outlet lines to
facilitate servicing the heater (see Fig. 29).
B For installation on a private well system with the use
of a pressure tank, the lowest pressure range setting
recommended is 40-60 psi (2.75 and 4.15 bar).
3.10 Water quality
Water quality can have an impact on appliance
longevity and may not be covered under the
manufacturer's warranty.
For water analysis data call your local water department,
or if on a well, have well water analyzed periodically. If
water quality exceeds one or more of the values
specified below, Bosch recommends installing a water
conditioner or softener.
Warning: This heater is not approved
for preheated water applications.
See chapter 3.11 for approved
recirculating application.
HOT
COLD
Description Max. Levels
pH pH 6.5 - 8.5
TDS (total Dissolved
Solids)
mg/l or ppm 500
Total hardness mg/l or ppm
100
(6 grains)
Aluminum mg/l or ppm 2.0
Chlorides mg/l or ppm 250
Copper mg/l or ppm 1.0
Iron mg/l or ppm 0.3
Manganese mg/l or ppm 0.05
Zinc mg/l or ppm 5.0
Table 9