Bosch Appliances APC-AMC2-4W Home Security System User Manual


 
44 en | Installing AMC2 4W
F.01U.024.965 | V.4 | 2006.09 Installation manual Bosch Security Systems
Fig. 5.21 Location of relay output jumpers (bottom side)
5.12 Connecting Analog Input Devices
The AMC2 4W has eight analog inputs, for example, for poten-
tial free lock mechanisms or to detect if a lock is closed or
open. The inputs will be connected to the 2-pin pluggable
screw connectors: S3, S4, S8, S9, S15, S16, S20, and S21 - see
Figure 7.5.