5
Specifications
Siren Section
Input Voltage - 10 to 16 VDC, negative ground (earth) - Models 4012 and 4013
20 to 30 VDC, negative ground (earth) - Models 4024 and 4025
Operating Current (Day) - 9.2 Amps @ 13.8V with 11-ohm load (100W Spkr) - Models 4012 and 4013
4.6 Amps @ 27.6V with 11-ohm load (100W Spkr) - Models 4024 and 4025
Operating Current (Night) - 0.8 Amps @ 13.8V with 11-ohm load (100W Spkr) - Models 4012 and 4013
0.4 Amps @ 27.6V with 11-ohm load (100W Spkr) - Models 4024 and 4025
Operating Temperature - -35°C to +85°C
Standby Current: 25 ma If direct to battery, 0 ma w/Ignition OFF if through vehicle ignition switch
(recommended)
Voltage Output ( approx. ) 70V peak-to-peak (Day)
4.2V peak to peak (Night)
Weight - 1.08 Kg (with mounting brackets)
Audio Section
Audio Response - 3 dB down points - 500 to 3000 Hz.
1000 Hz. 0 dB Reference
Audio Distortion - 10% or less below clipping.
MAINTENANCE
Your Code 3
®
4000 series siren has been designed to provide trouble free service. In case of difficulty, see
Troubleshooting. Also check for shorted or open wires. The primary cause of short circuits has
been found to be wires passing through firewalls, roofs, etc. If further difficulty persists, contact the factory for
troubleshooting advice or return instructions. Code 3
®
maintains a complete parts inventory and service facility
at the factory and will repair or replace (at the factorys option) any unit found to be defective under normal use
and in warranty. Any attempt to service a unit in warranty by anyone other than a factory authorized technician
without express written consent by the factory, will void the warranty. Units out of warranty can be repaired at
the factory for a nominal charge on either a flat rate or parts and labor basis. Contact the factory for details and
return instructions. Code 3
®
is not liable for any incidental charges related to the repair or replacement of a unit
unless otherwise expressly agreed to in writing.