Bissell 7340 Vacuum Cleaner User Manual


 
Your Flip It can be stored Ready-to-Use, by leav-
ing water and formula in the unit. Be sure to
remove wet Gentle Clean™ Pad before storing.
Storing The Flip-It
Troubleshooting
Water & Formula are draining out from the clean tank.
Possible Causes Remedies
1. Clean Tank Black Cap & Valve are not on tight 1. Remove Black Cap & Value
and attach tightly
2.
Clean Tank Black Cap & Valve are cross threaded 2. Remove Black Cap & Valve
and make sure it is screwed on
straight and tightly
No suction
Possible Causes Remedies
1. Filter may be dirty or clogged 1. Remove filter from the Dirty
Tank and clean
2.
Wet vacuum nozzle may not be on properly 2. Make sure Wet Vacuum Nozzle is
on tight and snapped into place
3.
Tank is full 3. Empty Tank
4.
Filter is wet 4. Make sure filter is completely dry
before placing back into the unit
.
5. Something is caught and clogging the air path 5. Unplug unit. Remove Wet Clean
Nozzle and insert a blunt object
into the air path to remove any
potential clog
.
Water is not flowing
Possible Causes Remedies
1. Clean Tank is not inserted properly 1. Remove Tank and reinsert into
the unit
WARNING:
To reduce the risk of
fire, electric shock or
injury unplug from outlet
before servicing.
Tip:
If the Pleated Filter is rinsed
with warm water to clean,
it is recommended to leave
it out of the unit to air dry
before placing it back in
the unit.
10
www.bissell.com 800.237.7691