Bissell 1400 Vacuum Cleaner User Manual


 
Troubleshooting
Cleaner won’t run.
Possible Causes Remedies
Power cord not plugged in Check electrical plug
Blown fuse/tripped breaker Replace household fuse or reset breaker
Reduced spray or no spray.
Possible Causes Remedies
Spray Nozzle clogged Clean Spray Nozzle
Clean/Solution Tank empty Check/Refill Tank
Clean/Solution Tank insert clogged Clean insert at bottom of Clean/Solution Tank
Pump needs priming Gently lift Clean/Solution Tank up and down
while depressing the Spray Trigger
OR Gently squeeze clean tank while depressing
Spray Trigger
Deep Cleaner Won’t pick up cleaning solution.
Possible Cause Remedies
Poor Upholstery/Carpet Tool position Reposition Upholstery/Carpet Tool on surface,
follow recommended cleaning procedures
Dirty/Collection Tank is full Empty Dirty/Collection Tank
Upholstery/Carpet Tool Brush worn Replace with new Brush
Excess solution in Vacuum Flex Hose Lift Tool and point upwards to allow water in
Incorrect Cleaning Formula Hose to flow into the Dirty/Collection Tank
Use BISSELL Little Green formula only
TurboBrush attachment-Brush will not turn.
Possible Causes Remedies
Incorrect switch position on TurboBrush Reposition switch to Brush position
No Suction on TurboBrush attachment.
Possible Causes Remedies
Incorrect switch position on TurboBrush Reposition switch to suction position