Bionaire BWM5075C Humidifier User Manual


 
20.If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similarly qualified person.
PLEASE SAVE THESE INSTRUCTIONS
Please note that this is an electrical
appliance, and requires attention when
in use.
How Your Warm Mist Humidifier Works
Your Bionaire™ Warm Mist Humidifier is designed
to allow the proper amount of water to flow out of
the tank and through the water purification filter.
The filter takes most of the minerals and sediment
out of the water before the water enters the
heating chamber where the Electronic Thermal
Control heating element warms the water. Air is
drawn in through the grill openings located in the
back of the unit and mixed with steam in the
misting chamber. The warm mist is then
dispersed out of the top of the misting chamber
through the outlet grill and into the room.
NOTE: A humidity level below 30% can be
unhealthy and uncomfortable. The recommended
humidity level is between 45%-55%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is disconnected from
the electrical outlet and the power knob is in
the 0 - off position.
2. Select a location for your humidifier, on a flat
surface, about 10cm away from the wall. Do
not place your humidifier on furniture. A floor
location that will not be damaged by moisture
is best.
3. Remove the water tank (see Figure 1). Remove
the Water Purification Filter, and hold it under a
cold running tap for at least 1 minute to ensure
it is thoroughly wet. Then replace it in the water
tray.
4. Make sure the water tray is free of foreign
objects by removing the Mist Chamber. To
remove this stack you must move the Safety
Lock (M) that secures both parts in place.
(Replace the Mist Chamber over the heating
element and make sure that the Safety Lock
knob is in the "Lock" position).
Filling the Water Tank
NOTE: This humidifier holds about 5.5 litres of
water in the tank and humidifier base. The
humidifier will produce up to 11.5 litres of moisture
over a 24-hour period.
1. Be sure the humidifier is disconnected from
the electrical outlet and the power knob is in
the 0 - off position. Remove the water tank.
2. Twist off the tank cap located on the bottom of
the reservoir by turning counter clockwise and
fill the water tank with cool, fresh water. Do
not fill with warm water as this may cause
leaking.
3. After filling the tank, replace the tank cap by
firmly turning clockwise and then replace the
water tank on the base. The tank will
immediately begin to empty into the base.
4. Plug the power cord into a convenient and
suitable power supply.
OPERATING INSTRUCTIONS (See Fig 2)
IMPORTANT
When using the water purification filter in the
humidifier for the first time, or after a period of
non-use (i.e. 48 hours), pre-soak the filter under a
cold running tap for 1 minute. Replace the filter in
the unit and allow 5 minutes for the water to pass.
Then, carefully lift the water tank and check if the
water tray (I) is 2/3 full of water. If not, replace the
water tank and wait a further 5 minutes until the
water reaches the desired level.
DO NOT switch on the humidifier until the water
tray is 2/3 full of water.
1. Turn the power knob to the I position. It is
normal for the humidifier to take about 2-3
minutes to warm up and begin to mist.
2. The Medicine Cup (B) is located on the top of
the Mist Chamber (A). To use, pour designated
humidifier medication into the groove.
DO NOT add medication to the water tank
DO NOT add medication to the medicine cup
when the unit is already operating.
Nightlight
1. To activate nightlight( ), move the knob to the
on (I) position.
2. To maximize bulb life, turn the nightlight ( )
off (O) during the day.
RESET PROCEDURE
NOTE: When the water tank is empty and the
water in the Heating Chamber is almost empty,
the re-fill light (red) will illuminate and the
Automatic Shut-off will activate. The unit will not
operate again until you refill the water tank and
reset the humidifier.
1. Turn the power knob anti-clockwise on to
RESET( ) .
2. Unplug the unit.
3. Remove and refill the water tank.Replace the
tank onto the base.
4. Wait 5 minutes for the Automatic Shut-Off to reset.
5. After the 5 minutes, plug in the unit and turn
32
Congratulations
By choosing a Bionaire™ humidifier, you have
chosen one of the finest humidifiers on the market
today
PLEASE READ AND SAVE THESE
IMPORTANT INSTRUCTIONS.
NOTE: Before reading these instructions,
please refer to the corresponding
illustrations
Descriptions (See fig 1/2)
A. Mist Chamber
B. Medicine Cup
C. Humidifier Housing
D. Power Knob
E. Night Light Control
F Night Light
GTank Handle
H. Tank
I. Tank Cap
J. Humidifier Base
K. Water Purification Filter
L. Water Tray
M. Safety Lock
N. Heating Element
SAFETY PRECAUTIONS
When using electrical appliances, basic safety
precautions should always be followed to reduce
the risk of fire, electric shock, and injury to
persons, including the following:
1. Read all instructions before using the
appliance.
2. To avoid fire or shock hazard, plug the
appliance directly into an electrical outlet and
fully insert the plug.
3. Keep the cord out of heavy traffic areas. To
avoid fire hazard, NEVER put the cord under
rugs, or near radiator, stoves, or heaters.
4. DO NOT place humidifier near heat sources
such as stoves, radiators, and heaters. Do
locate your humidifier on an inside wall near
an electrical outlet. The humidifier should be
at least 10cm/4" away from the wall for best
results.
5. WARNING: This humidifier produces hot
steam and therefore should not be placed in
an area where it is accessible to children.
Never use a humidifier in a closed room. (i.e:
doors and windows closed) as it may result in
excessive humidity.
6. WARNING: Do not attempt to refill humidifier
without first unplugging the unit from it's
electrical outlet. Be sure to pull by the plug and
not the cord.
7. NEVER drop or insert any object into any
openings. DO NOT place hands, face, or body
directly over or near Moisture Outlet while unit
is in operation. DO NOT cover Moisture Outlet
or place anything over it while the unit is
operating.
8. DO NOT operate any appliance with a
damaged cord or plug, after the appliance
malfunctions, or if it has been dropped or
amaged in any manner. Return appliance to
manufacturer for examination, electrical or
mechanical adjustment, or repair.
9. Use appliance only for intended household use
as described in this manual. Any other use not
recommended by the manufacturer may cause
fire, electric shock, or injury to persons. The
use of attachments not recommended or sold
by The Holmes Group, may cause hazards.
10.DO NOT use outdoors.
11. Always place humidifier on a firm, flat, level
surface. A waterproof mat or pad is
recommended for under the humidifier.
NEVER place it on a surface that may become
damaged by exposure to water and moisture
(i.e. finished floor).
12.DO NOT allow the Moisture Outlet to directly
face the wall. Moisture could cause damage,
particularly to wallpaper.
13.Humidifier should be unplugged when not in
use.
14.NEVER tilt, move, or attempt to empty unit
while it is operating. Shut off and unplug
before removing the water tank and moving
the unit. DO NOT attempt to remove the water
tank within 15 minutes after the humidifier is
turned off and unplugged. Serious injury may
result.
15.This humidifier requires regular maintenance
to operate appropriately. Refer to cleaning and
maintenance procedures.
16.NEVER use detergents, petrol, glass cleaner,
furniture polish, paint thinner, or other
household solvents to clean any part of the
humidifier.
17.Excessive humidity in a room can cause water
condensation on windows and some furniture.
If this happens, turn the humidifier OFF
18.Do not use humidifier in an area where
humidity level is in excess of 55%.
19.DO NOT attempt to repair or adjust any
electrical or mechanical functions on this unit.
The inside of the unit contains no user
serviceable parts. All servicing should be
performed by qualified personnel only.
U.K. and IRELAND