ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 19
3. Verify that the ON indicator (Figure 10) on the control box
is LIT. This means that power is being supplied to the control
box.
4. In the manual mode the pump will run continuously. Pay
close attention when running the pump in this mode.
DAMAGE to the pump may occur if pump is not immersed
in water.
5. To operate the pump automatically (float switches), place the
3-position operation switch in the AUTO position (Figure 11).
6. In the AUTO mode the pump will run as long as there is a
sufficient amount of water. This amount is determined by
the setting of the float switches. The
stop float
switch
contacts will open when the water level is low and power
will be removed from the pump's motor.
Once the water level has risen back to the appropriate
level the
start float
switch contacts will close and power
will be restored to the pump's motor.
Figure 10. Control Box Power ON Indicator
Figure 11. Manual-Off-Auto SW. (Auto Position)
Reset
1. When the overload module detects an overload, the unit
will shut down. Check the unit and remove cause of overload.
2. Let the unit cool down and press the RESET button (see
Figure 12) on the front of the control box to reset the unit
(restore power).
Shut-Down
1. Place the 3-position operation switch on the control box to
the OFF position (Figure 13).
2. Verify that the control box power ON light is OFF.
3. Turn the circuit breaker or quick disconnect switch to the
OFF position.
Figure 13. Manual-Off-Auto SW. (OFF Position)
Control Box Setup
1. From the voltage source set the circuit breaker or quick
disconnect switch to the ON position.
2. For manual operation of the pump, place the 3-position
operation switch (Figure 9) on the control box in the
MANUAL position.
Figure 9. Manual-Off-Auto SW. (Manual Position)
ST-4125D/ST-6125D — SETUP
Figure 12. RESET Button