Barnett Engineering ARU CV2 Home Security System User Manual


 
Configuration using the PC 3-7
B1272M001 BARNETT ENGINEERING LTD. ProTalk Cv2
Enabled
When a point is enabled, alarm activities will be reported and it can be interrogated for
its current status. A disabled point does not produce alarms and cannot be interrogated.
Changing the enable flag does not alter any of the other settings for this point.
Default Point state: disabled.
Digital and Watchdog Points
Settings for Watchdog points are the same as for Digital points.
Alarm State
Points can be set to register an alarm in two ways: only when the alarm condition is
present, or latched when an alarm condition is first detected. Latched operation means
that the alarm is set when the input change is first detected and will remain in that state
until the group it is using is acknowledged. If the alarm is not latched, it will be
removed as an alarm when the input condition returns to normal.
Default alarm state: when active.
DTMF Tag
The DTMF Tag is used to generate signaling messages for remote equipment. If a
DTMF tag is available, it will be sent if the [SIGNAL] command is present in the
Directory.
The tag can consist of 1 to 7 digits and may use any of the 16 DTMF digits including A,
B, C, and D.
Default DTMF Tag: empty string - no signaling.
Interval Point
An Interval Point uses only the common settings. It cannot generate alarms, but can be
interrogated to obtain readings.
Totalizer Point
Totalizers cannot generate alarms, but can be interrogated to obtain readings. In addition
to the common ones, the totalizer also has the these settings:
Decimal Place
A decimal place can be inserted into the spoken message for a totalizer. Five decimal
locations are available:
XXXXX.
XXXX.Y
XXX.YY
XX.YYY
X.YYYY