Bard Q24H1 Heat Pump User Manual


 
Manual 2100-519C
Page 22 of 42
Bard Part #8403-060
Thermostat
Brown/White
Red/White
Yellow
Blue
Brown
Orange
Orange
Red/Yellow
Black/White
R
Y
L
W1
B
W2
E
C
W3
O1
G
C
E
Aux
O/B
Y
RR
Y1
L
O/B
W2
Bard Part #8403-058
W1/E
C
G
Thermostat #TH522001151
MIS-2687
Rc
REMOTE THERMOSTAT WIRING DIAGRAM
"X" THERMOSTAT OPTION
Low Voltage
Terminal Block
9
10
6
5
3
11
8
Plug #2
1
12
7
2
G
4
1
1
Factory installed jumper.
A
FIGURE 17A
REMOTE THERMOSTAT WIRING DIAGRAM
“X” THERMOSTAT OPTION
NOTE: On option X or A the CS2000A* (or other field
provided means to control ventilation) must be
used if any of the motorized ventilation options
are installed.
VENTILATOR OR DAMPER