Barco DP90 Fan User Manual


 
2. Servicing the liquid cooling circuit
abc d e f
M
F
Image 2-7
4. Couple the filled syringe to the inlet of the cooling circuit and press the cooling liquid inside the circuit.
Caution: Position the empty bottle above the liquid circuit (on top of projector).
OUT
a
b
Image 2-8
Filling co oling liquid circuit
5. Disconnect thesyringe from the coolingcircuit andrepe at from step 3un til coolingliquid comesout the outletof the coolingcircuit.
R59770032 COOLING LIQUID REFURBISHMENT 07/12/2006
11