Troubleshooting
Problem Possible Cause Solution
Water drips from spout for a
few minutes after the unit is
turned off.
Normal clearing of spout.
Not a problem.
Debris in aerator.
Remove and clear debris.
Water drips constantly from
spout when water is turned
off.
Valve cartridge(s) faulty. Replace valve cartridge(s).
Water pools at base of spout. Diverter faulty Replace diverter.
Scale Removal
The Raindance Air 1-jet handshower incorporates the
Rubit
TM
cleaning system. If scale deposits are noticed
in the spray channels, turn the water on lightly and
rub the spray channels with a finger or a sponge.
If scale deposits are noticed on the spray face, pour
about 3/4” of a commercial scale remover, such as
Lime-Away
TM
or CLR
TM
,into a shallow dish. Dilute the
remover according to the label instructions.
Soak only the spray face in the solution for the
amount of time specified on the label.
Reinstall the handshower. Turn on the water and al
-
low the handshower to flush for at least one minute.
Rinse the handshower with clear water.