Axor 06064XX0 Plumbing Product User Manual


 
9
Install the carrier plate gasket and carrier plate
with the carrier plate screws.
Press the escutcheon very firmly over the carrier
plate, so that the strips of Duotec interlock, produc-
ing a very firm hold.
Install the handle: Tighten the handle screw,
using a 3 mm Allen wrench. For proper operation
of the valve, the handle screw must engage the
slot milled into the brass on the cartridge.
Set the high temperature limit stop (optional) -- see
page 11.
Justify the handle.
Justify the Handle
Tools required:
Thermometer
3 mm Allen wrench (included with trim kit)
Turn the valve on. Place the thermometer in the
water stream.
Turn the temperature control knob until the water
coming out measures 100° on the thermometer.
Turn the water off using the lever part of the
handle.
Use the 3 mm Allen wrench to loosen the set screw
on the bottom of the handle. Remove the handle
from the valve (1).
Hold the lever in one hand. With the other hand,
turn the temperature control knob approximately
½ turn clockwise (2a). Then, without pressing
inward on it, turn it counter-clockwise until it is
positioned vertically and hits the safety stop (2b).
Reinstall the handle and tighten the set screw (3).
2
a
b
English