Avalon Stoves 745 Stove User Manual


 
38 Optional Equipment
Travis Industries 93508133 4020509
Outside Air Installation (for wood stoves only)
This pedestal has an internal air duct that may be used to direct air to the combustion chamber.
Follow the directions below prior to installing the stove or attaching the pedestal.
! Outside air is required for mobile home installations and in certain localities.
+ Read the section "Outside Air Requirements" in the owner's manual prior to installing outside air.
1 Before placing the stove on pedestal, determine the location of the hole that is cut through the
floor protection and floor. The illustration to the right details the location where this hole may be cut in
relation to the faceplate of the stove. Cut a hole at least 16 square inches in area that does not
interfere with structural members of the home.
17"
16"
26"
18-3/4"
Outside air may be drawn
from this area underneath
the pedestal
(min. 16 square inches)
Pedestal Base
(without dowels)
Top View
The faceplate of the
Pendleton (745/790) and
Rainier (945/990) is 1-1/8" in
front of the forward edge of
the pedestal base.
FRONT
2 Place the included screen (or other screen) over the hole to act as a rodent barrier. It may be
attached above or below the floor. Secure the screen with the included staples.
OUTSIDE AIR EQUIPMENT
Staples are used to
attach the screen to
the floor.
Screen is used to prevent
rodents from entering.
Insulation is used to seal the
side edges of the pedestal .
Cover plate is used
to block off room air .
3 Prop the front of the stove up 12" and pry out the outside air knockout with a large screwdriver.
Outside Air Knock-Out
Drop Chute
Knock-Out
(990 only)
Rear Blower Knock-Outs
Ashpan Pedestal/Air Boot
Outside Air Knock-Out
(990 only)
DO NOT REMOVE
FRONT OF STOVE
5 The cover plate seals the area around the air control rod. Remove the two screws and bridge
from the cover plate. Slide the cover plate underneath the air control rod and re-attach the bridge.