Avalon Stoves 745 Stove User Manual


 
Insert Installation (for qualified installers only) 17
Travis Industries 93508133 4020509
SAFETY NOTICE:
Please read this entire manual before you install and use your new
room heater. Failure to follow instructions may result in property
damage, bodily injury, or even death. Contact local building or fire
officials about restrictions and installation inspection requirements
in your area.
Planning The Installation
We suggest that you have an authorized Travis Industries dealer install your stove. If you install the
stove yourself, your authorized dealer should review your plans for installation.
Check with local building officials for any permits required for installation of this stove and notify your
insurance company before proceeding with installation.
Preparation for Installation
Check for damage to the exterior of the inserts (dents should be reported, scratches can be fixed by
applying touch up paint).
Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place).
The stove can be lightened by removing the firebricks and baffle. (pg 26) - replace before operation.
Insert Installation Considerations
This insert is approved for installation into an existing masonry or zero clearance (metal) fireplace.
Depending upon your installation concerns, several options are yours to provide the most desirable
installation. The sections that follow detail the requirements that must be met for a safe installation.
To further help installation, the most common types of installations are explained in table below. Prior
to installing your insert make a detailed plan with dimensions to double-check them against all of the
requirements listed.
Installation Type Considerations
Insert with Positive Flue (Full Reline)
(Page 21)
Utilizes existing masonry or zero clearance fireplace
Provides best draft
Easiest to clean
Insert with Direct Connect Flue
(Page 21 and 22)
Utilizes existing masonry or zero clearance fireplace
Provides good draft
Requires fireplace block-off plate - see page 18
Insert with Face Seal Connection
(Page 22)
Utilizes existing masonry fireplaces with cross section
of 28" to 144" (not approved for zero
clearance fireplaces)
Provides okay draft
Easiest to install
Requires the optional surround panels and insulation
(see "Surround Panels" on page 42).
Surround Panels
The insert must be installed with surround panels (see page 42).