Aube Technologies TH106 Thermostat User Manual


 
23/01/02 920-106-001-00-1-B 4/4
WARRANTY
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original purchase from authorized dealers.
During this period, AUBE technologies inc. will repair or replace the product with a new or of equivalent quality at AUBE'S option, without charge, any product proven defec-
tive in normal use.
Warranty does not cover transportation costs. Nor does it cover a product subjected to misuse or accidental damage. This warranty does not cover the cost of installation,
removal or reinstallation.
This limited warranty is in lieu of all other warranties, obligations or liabilities expressed or implied by the company. In no event shall AUBE technologies inc. be liable for con-
sequential or incidental damages resulting from installation of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts, or the
exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and
you may also have other rights which vary from state to state.
The defective product and the original sale receipt must be returned to the original dealer or shipped pre-paid, insured and addressed to:
Aube technologies inc.
705, Montrichard
Iberville (Quebec)
Canada J2X 5K8
www.aubetech.com
service@aubetech.com
If you have any questions concerning the installation or programming of this product, please call our technical assistance at (450) 358-4600 for the Montreal area or
1-800-831-AUBE for outside area, Monday to Friday between 8:30 AM and 5:00 PM Eastern time.
PROBLEMS AND SOLUTIONS
PROBLEMS
CAUSES SOLUTIONS
- No display - Circuit breaker is open - Check 120 / 240 VAC presence at the thermostat
- Power failure
- Open linear limit control
- The LCD disappears but reappears - The thermal protection unit on the baseboard heater - Ensure that the baseboard heater is not obstructed by
after a 2 to 3 minute period opens after a power failure or a malfunction furniture or curtains. Also verify that the linear limit
control of the thermal protection unit is not touching
the heating element
- The thermostat is hot - In normal use at full capacity (4000 W), the housing
temperature of the thermostat can reach 35 to 40 °C
- The thermostat is loosing the time but not the programming - Power failure more than 2 hours
- Room temperature shown is wrong - A draft is near the thermostat - Eliminate the draft
- Heating system always on - Bad installation - Check installation
- The thermostat displays heating but heating system is - Bad installation - Check installation
not turned on
- Programs do not change as you want - Incorrect programming hours - Check actual time in AM & PM as well as program
- Wrong programming mode selected times (AM is not displayed)
- Make sure operating mode is set to AUTO
- Erratic or dim display - For a 500 W or less installation, the display could appear
dim after the first power-up or a long power failure when
the thermostat is in heat mode. See first power-up
section