Atlona AT-H2H-88M Plumbing Product User Manual


 
24
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Command Feedback Description
IPCFG IP Addr : x.x.x.x
Netmask : x.x.x.x
Gateway : x.x.x.x
IP Port: x.x.x
Displays IP address configuration
IPTimeout XX IPTimeout XX
(Ex. IPTimout120)
Determines amount of seconds of inactivity before TCP/IP
disconnects
IPQuit IPQuit Logs out of TCP/IP
IPAddUser TCP/IP username & password list:
- user password
- user password
- user password
Will display a list of users
IPAddUser [X] [Y] TCP/IP user was added Add a user for TCP/IP control. X=User Y=Password
Ex. IPAddUser Atlona 1234 (User=Atlona 1234=Password)
Each command or feedback is terminated with a carriage return.
Note: If the command fails or is incorrect the feedback should be “Command FAILED”
TCP/IP Commands
RS-232 & TCP/IP Control Commands
The command codes are case sensitive, do not change capitalization, spacing, or lettering.
Command Feedback Description
PWON PWON Power on
PWOFF PWOFF Power off
PWSTA PWx Will display the power status of the matrix (ex. Power is on = PWON)
Version (Firmware #) Brings up the current firmware version
Type (Model #) Brings up the model information
Lock Lock Locks the front panel of the matrix so no buttons are active
Unlock Unlock Unlocks the front panel of the matrix, enabling the buttons again
All# x1AVx1,x2AVx2,... Resets all inputs to corresponding outputs (in3 to out3)
x1$ x1$ Turns off output channel (to turn off output 3 = x3$)
x1All x1All Sets selected input to all outputs
(x3All would set input 3 to all)
x1AVx2 x1AVx2 Switch input to output (input 3 to output 2 = x3AVx2)
x1AVx2,x3,x4 x1AVx2,x3,x4 Switch input to multiple outputs (input 3 = x3AVx1,x2)
IRON IRON Turns on the IR receiver
IROFF IROFF Turns off the IR receiver
Statusx1 x7AVx1 Shows what input is connected to selected output
Status x1AVx1,x2AVx2,
x3AVx4, ....
Displays which inputs are currently connected to which outputs
SaveY (ex. Save2) SaveY (ex. Save2) Saves settings for future use, preset options 0 to 4
RecallY (ex. Recall2) RecallY (ex. Recall2) Recalls saved settings for the number you selected
ClearY (ex. Clear2) ClearY (ex. Clear2) Erases the save for the number you selected
Mreset Mreset Sets matrix back to the default settings