Ariston GL4S Water Heater User Manual


 
MODEL GL 2.5 - GL 4
The GL 2.5 and GL 4 water heaters can be installed under the sink.
Fasten the supplied mounting bracket to the wall. Use screws that are suitable for the
wall material and the weight of the heater. Hang the water heater on the bracket. Tug
down wards on the heater to ensure that both “fingers” of the bracket are seated in the
mounting slots.
Wall
mounting
FIG. 3/2
G
H
E
A
Z
F
X
Y
T
FIG. 3/1
V
C
F
W
If you wish to install the unit vertically, with the piping connections on top, you will have to
be certain the tap on the side is plugged, the supplied Temperature and Pressure Relief
Valve will need to be installed on top. See location of T&P relief valve in Fig. 2/3.
5