1. DIFFERENTIAL
Determines the temperature above/below the temperature
setting at which the heating or cooling equipment will turn
on. For example, a heat temperature setting of 70°F with a
differential of 2° will result in the equipment turning on and
off to maintain the temperature between 68°F and 70°F. If the
second stage differential is also 2°, the second stage would
be used to ensure the temperature did not drop below 66°.
However, once the second stage is turned on, it will stay on
until the temperature again reaches the 70° setting. The default
setting for the first stage and second stage differential is 1°.
To change the differential settings:
1. Make sure the thermostat is in the OFF mode.
2. Press and hold both the and buttons for 3 seconds.
– The display will show the ADV. SETTINGS MENU.
3. Use the or button to highlight “SET DIFFERENTIAL”
and press the SELECT button.
– If the thermostat SINGLE/MULTI dip switch is set for
MULTI, two differentials will appear, if set for SINGLE,
only one will appear.
4. To cancel, press the BACK button. This will return you
to the ADV. SETTINGS MENU.
5. To change the first stage differential, press the and
button to raise or lower the setting. To change the second
stage differential, press the SELECT button.
6. To finish and return to the ADV. SETTINGS MENU, press
the SELECT button after the value(s) have been set.
For heat pumps – the auxiliary heat differential is the
same as the first stage differential in single-stage heat
pump applications and is the same as the second stage
differential for two-stage heat pump applications.