POWER & RESET OPTIONS
The equipment control module is powered from
24VAC. The thermostat is powered from the equipment
interface module and has a battery back-up option for
the clock.
The thermostat has a memory backup that saves the
thermostat settings in case of a power interruption.
The system settings will be retained but the clock will
reset after 90 seconds with no battery or equipment
control module power.
The reset button located under the battery cover can
be used to reset the thermostat to factory defaults. The
system settings will also be reset to default.
SETUP & TESTING
INSTALLER SETUP MENU
CHANGE SYSTEM SETTINGS
HOW TO ENTER THE INSTALLER SETUP MENU AND SELECT EQUIPMENT TO SETUP:


Press [MODE] to set system to OFF.
Press [MENU] to enter main menu.
Press and hold [SETUP][INSTALL
SETUP] appears.
Press [INSTALL SETUP] to enter installer setup menu.
Press
or 
Press [MENU]
Press [NEXT] to select option.
Press
or

Air Quality) option.
Press [NEXT] to select Outdoor Sensor setting or IAQ
(Indoor Air Quality) option.
System Settings can now be changed.
Press [NEXT] or [BACK] to page through the settings.
Press
or 
Press [DONE][CANCEL]
without saving.

is pressed within 60 seconds.

the thermostat by pressing the [RESET] button for 5
seconds.






EQUIPMENT TYPE SELECTION SWITCH (SW1)
This Home Comfort Control has the option of being used
in heat pump or heat/cool systems. Switch SW1 located
on the back of the thermostat’s face is used to select this
option. This setting is displayed in the Installer System
Settings under Equipment Type.
Note: Home Comfort Control reboots within 10 seconds
after switch position is changed.
HC
HP
SW1
HEAT/COOL

HC
HP
RESET
BUTTON