4 5
INSTALLATION INSTALLATION
EQUIPMENT CONTROL MODULE WIRING
Wire specifications:
18-24 gauge thermostat wire
Installation notes:
and re-tighten.
channels.
1 – Connection to terminal 1 at thermostat
2 – Connection to terminal 2 at thermostat
3 – Connection to terminal 3 at thermostat
RAT – Return air temperature sensor (optional)
LAT – Leaving air temperature sensor (optional)
ODT – Outdoor temperature sensor (optional)
C – 24VAC common
R – 24VAC
RC – 24VAC Cooling
RH – 24VAC Heating
W
W2
pump)
W3/B – Third stage heat (conventional)/reversing valve
(heat pump)
Y – First stage cooling (conventional)/first stage compressor
(heat pump)
Y2 – Second stage cooling (conventional)/second stage
compressor (heat pump).
Y3/0 – Third stage cooling (conventional)/reversing valve
(heat pump)
G – Fan
L – System fault indicator (heat pump only) (optional)
C
EQ – 24VAC common from heat pump for system fault
indicator (optional)
HUM – Humidifier
DHno & DHcom
DHnc & DHcom
VENT – Ventilation
EAC – Electronic Air Cleaner
OUTDOOR TEMPERATURE SENSOR
OPTIONAL WIRELESS OUTDOOR TEMPERATURE SENSOR
Outdoor temperature can be measured by installing an 8052 sensor (included) to the ODT terminals and enabling the
In heat pump mode the outdoor temperature sensor can be used to efficiently utilize an air source heat pump:
only the heat pump will be used to provide heating.
Indoor Air Quality functions can use the outdoor temperature sensor to:
Outdoor temperature sensor should
be mounted:
(north side recommended).
condensing lines.
Instructions for detailed directions regarding installation.
Outdoor Sensor