14 15
SYSTEM TEST MENU (CONTINUED)
While the equipment test is active the corresponding test information will be shown.
Press [NEXT] to accept the selection and proceed to the next test selection.
TEMPERATURE
EQUIPMENT TEST
SELECTION
HUMIDITY
OUTDOOR
TEMPERATURE
OUTPUT STATUS
TEST THAT
IS ACTIVE
SETUP & TESTING
Each equipment test will begin with the selection of turning on the output or stage as shown below.
Press
or to change the selection.
Press [NEXT] to accept the selection and proceed to the next step.
If YES is selected, the thermostat will test the corresponding output. If NO is selected, the thermostat will proceed
to the next step.
TEMPERATURE
EQUIPMENT TEST
SELECTION
HUMIDITY
OUTDOOR
TEMPERATURE
TEST TO BE RUN
SETUP & TESTING
SYSTEM TEST TABLES
Heat / Cool Heating Equipment Test
Heat Type W W2 Y Y2 G
Gas 1st Stage Test ON
Gas 2nd Stage Test ON ON
Electric 1st Stage Test ON ON
Electric 2nd Stage Test ON ON ON
Heat Pump Heating Equipment Test (Electric Heat)
Compressor
Stages
Aux
Stages W W2 Y Y2
O/B set to
GO B
1 1 1st Stage Test ON ON ON
1 1 2nd Stage Test ON ON ON ON
2 1 1st Stage Test ON ON ON
2 1 2nd Stage Test ON ON ON ON
2 1 3rd Stage Test ON ON ON ON ON
1 2 1st Stage Test ON ON ON
1 2 2nd Stage Test ON ON ON ON
1 2 3rd Stage Test ON ON ON ON ON
2 2 1st Stage Test ON ON ON
2 2 2nd Stage Test ON ON ON ON
2 2 3rd Stage Test ON ON ON ON ON
2 2 4th Stage Test ON ON ON ON ON ON
Note: System Variable 31, O/B operation selects O or B.
Heat Pump Heating Equipment Test (Gas Heat)
Compressor
Stages
Aux
Stages W W2 Y Y2
O/B set to
GO B
1 1 1st Stage Test ON ON ON
1 1 2nd Stage Test ON ON
2 1 1st Stage Test ON ON ON
2 1 2nd Stage Test ON ON ON ON
2 1 3rd Stage Test ON ON
1 2 1st Stage Test ON ON ON
1 2 2nd Stage Test ON ON
1 2 3rd Stage Test ON ON ON
2 2 1st Stage Test ON ON ON
2 2 2nd Stage Test ON ON ON ON
2 2 3rd Stage Test ON ON
2 2 4th Stage Test ON ON ON
Note: System Variable 31, O/B operation selects O or B.