A.O. Smith GWV - 200 Water Heater User Manual


 
Burkay - Genesis
Technical specifications
Gas data natural gas 2H (G20)
Input* kW 122.2 152.1 194.3
Output kW 99.0 123.3 157.5
Inlet pressure mbar 20 20 20
Burner pressure (Full Power) mbar 2 x 8.9 2 x 9.3 2 x 8.0
Gas consumption (Full Power)** m
3
/h 11.6 14.5 18.5
Diameter main orifice mm 2.31 2.31 2.31
Burners - 8 10 15
Max. flue gas temperature °C 130 130 130
Flue gas discharge (Full Power) kg/h 211.3 278.7 343.8
Gas data propane gas 3P (G31)
Input* kW 108.7 135.9 212
Output kW 90.0 112.5 175.5
Inlet pressure mbar 37 37 37
Burner pressure (Full Power) mbar 2x 13.3 2x 12.7 2x 14.5
Gas consumption (Full Power)** m
3
/h 7.8 9.7 15.1
Diameter main orifice mm 1.50 1.50 1.50
Burners - 8 10 15
Max. flue gas temperature °C 130 130 130
Flue gas discharge (Full Power) kg/h 208 268 369
Draw-off capacity***
Max. temperature setting °C 85 85 85
Continuous T=44°C l/h 1935 2410 3078
Continuous T=50°C l/h 1703 2121 2709
Continuous T=55°C l/h 1548 1928 2463
Electrical data
Power consumption W 200 210 350
Power supply VAC/Hz 230 (-15/+10%) / 50 (+/- 1 Hz)
General
Fan rotational speed at ignition r.p.m. 1620 1500 1800
Half load fan speed r.p.m. 2040 2340 2460
Full load fan speed r.p.m. 2340 2700 2820
Pressure differential Pa 80/66 89/75 107/192
Maximum working pressure bar 8
Transport
Weight empty kg 225 250 300
Weight incl. packaging kg 250 275 325
Width packaging mm 795 795 795
Height packaging mm 1075 1075 1075
Depth packaging mm 1605 1760 2165
GWV 120
GWV 150
GWV 200
* Gas data on gross value
** Gas consumption at 15°C and 1013.25 mbar
*** Draw-off capacities are based on the capacity of the heat exchanger
A Burkay - Genesis water heater should be installed in combination with a storage tank