18
G20 G30 G31
Inlet pressure mbar 20 30 37
Burner pressure mbar 10.5 30 37
Diameter main injector mm 3.50 1.95 1.95
Diameter pilot injector mm 2x0.27 0.22 0.22
G20 G30 G31 G20 G30 G31
Inlet pressure mbar 20 30 37 20 30 37
Burner pressure mbar 12.5 30 37 12.5 30 37
Diameter main injector mm 2.35 1.40 1.40 2.60 1.50 1.50
Diameter pilot injector mm 2x0.27 0.22 0.22 2x0.27 0.22 0.22
Procedure:
1. Close the main gas tap in the gas
supply.
2. Demount the burner (see “Cleaning”).
3. Replace the injector of the main
burner and the pilot burner with the
correct injectors from the conversion
set (see tables above).
4.a Conversion from natural gas to
LP- gas
- Put the pressure regulation of the
gas control block out of operation.
To do this the temperature
regulating knob should be pulled
straight forward. Turn the ‘no pr’
(no pressure regulation) screw
down tight (see Figure 10).
- Seal this setting with lacquer.
- Remount the burner in reverse
order.
- Open the main gas tap.
Unit EQ 115 EQ 155
Unit EQH 200
Description
Description