15
2.2.3 Removing and replacing
the inner door
(only for the EQ 115/155 models, see
Figure 7a).
Procedure:
1. Place lip A through the recess on the
right and subsequently slide it down
behind the steel wall. See to it that
both lower lips remain in front of the
metal wall.
2. Press lip B through the recess on
the left.
3. Subsequently slide lip B behind the
steel wall (see Figure 7a).
(only for the EQH 200 model, see Figure
7b).
Procedure:
1. Turn down both clamps (1).
2. Place the entire door into the
appliance and move the opening
over the burner venturi.
3. Turn both clamps outward (3),
pushing them over the edge of the
burner chamber.
2.3 Pilot adjustment
The pilot can be adjusted by means of
the regulating screw under the plastic
cover on the right hand side of the gas
control block.
Turn the screw clockwise to reduce the
gas pressure and anti clockwise to
increase the pressure. Care should be
taken to ensure the pilot covers the
thermocouple element correctly
2.4 Putting out of operation
1. For short periods of time the control
knob should be turned to (✸); the
pilot keeps burning.
2. For longer periods of time the knob
should be turned to the (●) position;
the pilot is extinguished.
3. Close the gas tap in the supply pipe.
In case of longer interruptions or in
the event of risk of frost it is
Figure 7a - Mounting the inside door
A
B
Figure 7b - Mounting the inside door
AOS 0520
IMD 0359
3
1
1
3