American Water Heater VG6250T76NV Series 100 Water Heater User Manual


 
11
inanalcoveorcloset,theentireoormustbecoveredbythepanel.
Failuretoheedthiswarningmayresultinarehazard.
Minimum clearances between water heater and combustible
constructionare0inchatthesidesandrear,5.5”(14.0cm)fromthe
frontand12”(30.5cm)fromtop.(Standardclearance.)Ifclearances
stated on the heater differ from standard clearances, install water
heater according to clearances stated on the heater.
Adequateclearance24”(61.0cm)forservicingthisapplianceshould
be considered before installation, such as changing the anodes, etc.
Aminimumclearanceof5.5”(14.0cm)mustbeallowedforaccess
to replaceable parts such as thermostats, drain valve, relief valve
and condensate drain.
When installing the heater, consideration must be given to proper
location. Location selected should be as close to the wall as practicable
and as centralized with the water piping system as possible.
FIGURE 4.
A gas water heater cannot operate properly without the correct amount
ofairforcombustion.Donotinstallinaconnedareasuchasacloset,
unless you provide air as shown in the “Locating The New Water
Heater”section.Neverobstructtheowofventilationair.Ifyouhave
any doubts or questions at all, call your gas supplier. Failure to provide
theproperamountofcombustionaircanresultinareorexplosion
and cause death, serious bodily injury, or property damage.
FIGURE 5.
If this water heater will be used in beauty shops, barber shops,
cleaning establishments, or self-service laundries with dry cleaning
equipment, it is imperative that the water heater or water heaters
be installed so that combustion and ventilation air be taken from
outside these areas.
Propellantsofaerosolspraysandvolatilecompounds,(cleaners,
chlorinebasedchemicals,refrigerants,etc.)inadditiontobeinghighly
ammableinmanycases,willalsoreacttoformcorrosivehydrochloric
acid when exposed to the combustion products of the water heater.
The results can be hazardous, and also cause product failure.
INSULATION BLANKETS
Insulation blankets are available to the general public for external
use on gas water heaters but are not necessary with these products.
The purpose of an insulation blanket is to reduce standby heat loss
encountered with storage tank heaters. Your water heater meets or
exceeds the Energy Policy Act standards with respect to insulation and
standby loss requirements, making an insulation blanket unnecessary.
Should you choose to apply an insulation blanket to this heater, you
shouldfollowtheseinstructions(Foridenticationofcomponents
mentionedbelow,seeFigure1).Failuretofollowtheseinstructionscan
restricttheairowrequiredforpropercombustion,potentiallyresulting
inre,asphyxiation,seriouspersonalinjuryordeath.
Do not apply insulation to the top of the water heater, as this will
interfere with safe operation of the blower assembly.
Do not cover the outer door, thermostat or temperature & pressure
relief valve.
Do notallowinsulationtocomewithin2”(5.1cm)oftheoorto
preventblockageofcombustionairowtotheburner.
Do not cover the instruction manual. Keep it on the side of the
water heater or nearby for future reference.
Do obtain new warning and instruction labels from the manufacturer
for placement on the blanket directly over the existing labels.
Do inspect the insulation blanket frequently to make certain it
doesnotsag,therebyobstructingcombustionairow.
AIR REQUIREMENTS
For safe operation an adequate supply of fresh uncontaminated
air for combustion and ventilation must be provided.
An insufficient supply of air can cause recirculation of combustion
products resulting in contamination that may be hazardous to life.