Amcor HWAM9KE Air Conditioner User Manual


 
55
GB
DISCONNECTING THE EXTERNAL UNIT
Notice: the quick-couplers are meant for one-off connection !
The guarantee does not cover multiple installation.
Should it be necessary to disconnect, then go about it as follows:
ask someone to help you operate the air conditioner via the remote control,
put the desired temperature at 18 °C
start the air conditioner, wait until you can also hear the compressor turning
unscrew the caps from the valves and shut the upper valve (thin duct) with the
socket wrench
wait up to 1 minute: you will hear the sound of the compressor changing also
shut the lowest valve (thick duct) with the socket wrench
immediately switch the air conditioner off by taking the plug from the socket
after both valves have been shut completely put the protective caps back on
disconnect the same way as indicated for connecting; place the protective caps
on the quick-couplers
Notice: if you are in any doubt or uncertainty leave this work to the installer.