Amcor HWAM9KE Air Conditioner User Manual


 
43
Auto restart
The air conditioner will automatic restart when electricity is restored after a power
cut. If in doubt, check the settings.
Range of internal thermostat
The internal thermostat can be set at a desired temperature between 18 and 30 °C.
Note that whether the desired value is achieved depends on conditions in the room.
Range of heat pump function
The heat function can be used when the external temperature is approximately 10 °C
or higher.
Note that it may not operate properly at lower external temperatures.
Capacity
The required cooling or heating capacity depends greatly on the location and/or use
of the room where the air conditioner is installed. Strong sunlight and the presence
of people, lights or equipment create an additional heat load.
Normal living spaces require about 100 W per square metre of floor surface. In
strong sunlight or if other sources of heat are present, this may be as much as
350 W/m
2
.
For your air conditioner’s specifications, see pages 58/59.
Tip: on warm days, let the air conditioner cool the room as much as possible during
the night. Cold walls and furniture will help to keep the room pleasant during use.
Avoid strong sunlight.
Emergency start
In the event of a problem, the air conditioner can be operated using the emergency
button under the panel in the interior unit. Open the front panel and press the
button.
The air conditioner will:
- heat if the room temperature is 20 °C or less
- cool if the room temperature is 25 °C or more
and for values in between: dehumidify in a model without a heat pump and in a
model with a heat pump in fan mode.
IMPORTANT
GB