Nilfisk-ALTO SR 1301 P Vacuum Cleaner User Manual


 
USER MANUAL
ENGLISH
SR 1301 P 1463388000(1)2008-05 A
27
HOPPER HYDRAULIC LIFTING SYSTEM OIL
LEVEL CHECK
WARNING!
This procedure must be performed with the
hopper (4) fully retracted (as shown in the gure).
Engage the parking brake with the pedal (82) and the lever 1.
(75).
Turn the ignition key (69) to “0”.2.
Open the hood (23) and fasten it with the support rod (55).3.
Check that the oil level in the tank (41) is between the 4.
minimum (MIN) and maximum (MAX) marks shown in Fig.
25.
If necessary, add oil through the plug (A, Fig. 25), using 5.
the oil speci ed in Technical Data paragraph.
Remove the support rod (55) and close the hood (23).6.
DRIVE SYSTEM OIL LEVEL CHECK
Engage the parking brake with the pedal (82) and the lever 1.
(75).
Turn the ignition key (69) to “0”.2.
Open the hood (23) and fasten it with the support rod (55).3.
Check that the oil level in the tank (28) is between the 4.
minimum (MIN) and maximum (MAX) marks shown in Fig.
26.
If necessary, add engine oil SAE 10 W 40 through the plug 5.
(A, Fig. 26).
Remove the support rod (55) and close the hood (23).6.
P100238
Figure 25
MIN
MAX
A
P100239
Figure 26