Nilfisk-ALTO ATTIX 751-2M Vacuum Cleaner User Manual


 
6
english
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
1)
Option depending on model
4.2 Switching on the
vacuum cleaner
4.2.1 Switch position “I”
1. Turn the switch to position
„I“.
The vacuum cleaner motor
starts.
4.2.2 Switch position „auto“
Before switching the switch to position
„auto“, ensure that the tool connected
to the appliance socket is switched off.
1. Turn the switch to position
„auto“. The vacuum cleaner mo-
tor starts when the connected
appliance is switched on.
2. When the power tool is switched
off the vacuum cleaner contin-
ues to run for a short moment
so that any dust in the suction
hose is conveyed to the safety
filter bag.
4.1.3 Connecting electrical
appliances
1. Ensure that the electrical
appliance is switched off.
2. Connect the electrical appli-
ance to the appliance socket
on the control panel.
To comply with regulations, only ap-
proved dust producing tools should
be connected.
The maximum power consumption
of the connected power tool is stat-
ed in section 9.4 “Technical data”.
The hose diameter and the setting
for the suction hose diameter must
be the same.
Hose
ø
Hose diameter
setting
ø27 ø27
ø32 ø32
ø36 ø36
ø50 ø50
0
0
0
0
0
3
3
6
5
2
2
7
0
0
0
0
0
3
3
6
5
2
2
7
The hose diameter and the setting
for the suction hose diameter must
be the same.
Hose
ø
Hose diameter
setting
ø27 ø27
ø32 ø32
ø36 ø36
ø50 ø50
4.2.3 Suction power control
The motor speed and the suc-
tion power can be varied with
the suction power control. This
allows precise adaptation of
the suction power for different
cleaning tasks.
0
0
0
0
0
3
3
6
5
2
2
7
4.3 Check volume flow
monitor
Before picking up dust with maxi-
mum room concentration values:
1. Check that all the filters are
present and properly fitted.
2. When the motor is running,
hold the suction hose shut.
An acoustic warning sounds
after approx. 1 second.