Nilfisk-ALTO 530 Vacuum Cleaner User Manual


 
Page -20- CLARKE TECHNOLOGY 530 Upright Vacuum Operator's Manual
HOW TO REPLACE MOTOR
IMPORTANT: Disconnect machine before replacing
motor.
1. Detach bag (1).
2. Remove screw (2) and nut (3) at bottom of handle
tube.
3. Press the handle release pedal (9) and pull handle
down to horizontal position.
4. Remove handle tube from socket.
5. Remove screw (6).
6. Remove height adjustment knob (7).
7. Turn machine upside down.
8. Remove cover springs (8).
9. Remove retainer bar (19).
10. Remove bottom plate (10).
11. Remove fan cover (11).
12. Remove band (12).
13. Hold vacuum cleaner from the motor cover and turn
to the upright position. Remove motor cover.
14. Remove tunnels from motor (13, 14).
15. Remove screws (15, 16, 17, 18).
16. Disconnect cord from switch.
17. Disconnect connector.
18. Remove motor (fig. 11).
19. Replace new motor.
To assemble machine, follow above steps in a reverse
order.