Alliance Laundry Systems CS2000 Electric Heater User Manual


 
-25-
7. PROBLEMS DURING OPERATION AND START-UP
Problem Check
--------------------------------------------------------------------------------------------
Cycle does not start - doors not closed correctly
- emergency stop activated
- contact breaker or
electricity outage
--------------------------------------------------------------------------------------------
Control panel does not - fuses tripped
light up - emergency stop activated
- processor off
- electricity outage
--------------------------------------------------------------------------------------------
Cycle starts but drum - fuse of regulator tripped
does not turn - press yellow indicator light
on front side when it is on
--------------------------------------------------------------------------------------------
Cycle starts but water - water inlet closed
does not enter - pressure switch out of
service
- electronic valve out of
service
- fuse tripped
- electronic valve of inlet out
of service
--------------------------------------------------------------------------------------------
Cycle starts but water - pressure switch out of
inflow does not stop service
- electronic valve dirty
- tub pressure switch
clogged
- drainage valve still open
--------------------------------------------------------------------------------------------
Cycle starts but heating - required water level not
does not engage reached
- fuse tripped
- contact coil heating out of
service
- HS probe
--------------------------------------------------------------------------------------------
Heating is on but - resistor out of service
temperature does not rise