Air King KW(N207,P208)-20,000 Thermostat User Manual


 
Page 9
3. Installation and repair should be done by a qualified service person. The room
heater should be inspected before use and at least annually by a professional
service person. More frequent cleaning may be required due to excessive lint from
carpeting and other materials. It is imperative that the control compartments,
burners and circulating air passageways of the heater be kept clean.
CONNECTING TO GAS SUPPLY :
WARNING : Never connect an unregulated gas line to the heater.
An installer supplied, design certified gas pressure regulator must be installed to
bring the gas supply pressure down to 14 inches of water column.
IMPORTANT : Check gas line pressure before connecting heater to gas line.
Gas line pressure must not be higher than 14 inches of water. If gas line pressure is
higher, heater gas pressure regulator damage could occur.
CAUTION : Use only new, black iron or steel pipe. Internally-tinned copper
tubing may be used in certain areas. Check your local codes. Use pipe of large
enough diameter to allow proper gas volume to heater. If pipe is too small, undue
pressure loss will occur.
Typical Gas Supply Pipe Diameters
10,000 BTU/HR Model 3/8" or greater
20,000 BTU/HR Model 3/8" or greater
30,000 BTU/HR Model 3/8" or greater
CAUTION:
Use pipe joint sealant that is resistant to liquefied petroleum gases.
Install sediment trap in supply line as shown in Figure 8 Gas Connection. Locate
sediment trap where it is within reach for cleaning. Locate sediment trap where
trapped matter is not likely to freeze. A sediment trap traps moisture and
contaminants. This keeps them from going into heater controls. If sediment trap
is not installed or is installed wrong, heater may not run properly.
Figure 7