Aico RFD Smoke Alarm User Manual


 
MCP400 Manual Call Point
For use with Ei151TLR, Ei156TLR, Ei161R,
Ei164R or Ei166R alarms
Supplied complete with surface
mount box
Testing key supplied
Supplied with non-breakable
operating element
Suitable for use with Modifire
LPC approved, conforms to
BS EN 54-11
Ei159 Smoke Alarm
Locator Switch
This convenient unit allows the user to
locate the precise source of an
alarm in installations comprising three
or more units. Pressing the locator
button stops all the alarms sounding
except for the one that was the
source of the alarm.
The ideal way to quickly and easily
find the source of any alarm
Easy to install
Ideal for larger premises and HMOs
Auto reset within ten minutes
Minimises disturbance to other
residents
Suitable for use with any of the
140, 150 and 160 series alarms
Ei128R Relay Base - mains
powered only
For use with 140 and 160 series
Surface Mount Kit or pattress
5 amp relay with volt free contacts
Switchable for constant or pulse
operation
Allows signalling to door closers,
sounders, strobes etc
Suitable for use with Modifire
Ei128RBU Relay Base
- mains with rechargeable
back-up
For use with 140 and 160 series
5 Amp relay with volt free contacts
Switchable for constant or pulse
operation
Features rechargeable lithium back-
up cells with 10 yr+ life
Ideal for signalling to devices not
affected by a mains failure, such as
Warden Call Systems
MODIFIRE
A Modifire system is exceptionally simple
to design and install, thanks to its modular
design and unique Easi-fit technology.
Just tailor the system to meet the needs
of the premises. The Ei161R ionisation or
Ei166R optical alarm with rechargeable
back-up provides the starting point. Then
you can add extra alarms, call points and
locator switches as required, all
interconnected with PVC mains wiring
cable. Only one ‘R’ unit - Ei161R or Ei166R
- is necessary for each system.
BASIC SYSTEM (GUIDE ONLY)
System to cover escape routes only
Choose from Ei161R ionisation or Ei166R
optical alarms
Connect Manual Call points MCP400
into the circuit
INTERMEDIATE SYSTEM
(GUIDE ONLY)
System to cover escape routes AND
high risk areas
Install Ei161R or Ei166R alarm and add
further ionisation (Ei161), optical (Ei166)
and heat alarms (Ei164) as required to
a maximum of 20 alarms. The Ei128R
relay base counts as one alarm
Connect into the circuit Manual Call
Points MCP400 as required
Connect into the circuit Alarm Locator
Switches Ei159 as required
Mount an Ei128R or Ei128RBU relay base
behind the ‘R’ unit to signal warden call
devices, strobes, sounders etc
BASIC SYSTEM (GUIDE ONLY)
INTERMEDIATE SYSTEMS (GUIDE ONLY)
24