Aico 260 Series Smoke Alarm User Manual


 
9
Interconnect & Remote Control Feature
Ancillary Options For Ei260 Series
Bedroom BedroomLanding
Living
Room
Hallway
Kitchen
Bedroom BedroomLanding
Living
Room
Hallway
Kitchen
Smoke Alarm
CO Alarm
Smoke Alarm
CO Alarm
Alarm Control Switch
Audibility of
CO Alarm Only
Audibility when
CO & Smoke Alarms are
interconnected
Models Ei261ENRC & Ei261DENRC
Ei1529RC Alarm
Control Switch
Wall mounted
Supplied with surface box, can be
flush mounted using a standard
35mm deep electrical socket box.
Can be fitted anywhere in the system
For use when interconnecting Ei160RC
smoke/heat alarms with Ei260 Series
CO alarms
Allows Alarm Test, Hush, Locate and
Mains Check functions
Ei128RBU Relay
Internal 5 Amp relay with Volt-free '
clean' contacts
Contacts rated to 240V AC
Mains operated
10yr+ rechargeable cell back-up
For use with Ei128COV cover to enable
remote siting
Switchable pulse or continuous output options
Battery back-up allows contacts to switch
even if mains power supply fails
For use with Ei260 Series alarms only
SAB300 Strobe
Xenon beacon
Mains operated
3W Xenon tube,0.9Hz flash rate
For connection through an Ei128RBU relay
Available with clear ('C') or red ('R') lens
(add suffix to product code)
Integral mounting base
GSV415SA Gas
Solenoid Valve
Mains operated
For connection through an Ei128RBU relay
Closes internal valve when mains is applied
Push button reset
1/2 “ internal parallel pipe thread to ISO7-1
Ei261MEN & Ei261M
Replacement Sensor Module
Simple plug-in installation
Doubles life cycle of the product
'Ei261MEN' to suit models
Ei261ENRC/Ei261DENRC/Ei261DEN/Ei261EN
'Ei261M' to suit models Ei261D/Ei261
Ei260 Series
CO Alarms
Ei1529RC Control
Switch
230C
AC
Main
Supply
Ei160RC
Smoke/Heat Alarm
Ei160RC
Smoke/Heat Alarm
Ei160RC
Smoke/Heat Alarm
Wiring Diagram -
Ei1529RC Alarm Control Switch
The Problem
Audibility throughout the home is a priority,as a situation could
arise where a CO alarm is installed in a downstairs kitchen,which
has a fossil fuel burning appliance within it,and the alarm signal
may not be heard in the upstairs bedrooms or indeed other rooms.
The Solution!
Use the interconnect feature on the Ei261ENRC/Ei261DENRC to
connect to your existing Ei160RC smoke/heat alarm installation.
Then, you must introduce an Ei1529RC Alarm Control Switch
to provide control over the
whole system.
The interconnect feature allows the CO alarm to trigger all
Ei160RC mains smoke/heat alarms installed and vice-versa - giving
increased audibility in either a CO or fire situation. If all alarms are
sounding, pressing ‘Locate’ on the Ei1529RC Alarm Control Switch
will silence all the alarms except the alarm sensing a CO or fire
situation.This gives control over the system and allows occupants
to select the safest action and/or escape route.
Additionally, if found to be a false alarm,simply press ‘Hush’on the
Control Switch to silence the alarm.The entire alarm system can
also be tested regularly by pressing the ‘Test’switch.