4 - Front Panel Operation
50
6 - Using Slew Rates to Generate Waveforms
As shown in the previous examples there are a number of ways that you can generate custom waveforms.
Programmable slew rates provide additional flexibility when customizing waveforms. The following
figure illustrates how programmable slew rates are applied in the transient operating modes.
In example , an immediate slew rate of 50 volts/second is used whenever a new output voltage is
programmed. In example ô, a triggered slew rate of 50 volts/second steps the voltage level to its new
value. 50 volts/second becomes the new immediate slew rate in step mode. In example í, a triggered
slew rate of 50 volts/second is used at the start of the pulse. The immediate slew rate of infinity applies at
the trailing edge of the pulse. In example ÷, the slew rates are set by the values in the voltage slew list.
Figure 4-8. Programming Slew Rates
New VOLT level
TRIGGER
VOLT:T level
SLEW [0]
SLEW [1]
APPLIED
LIST
COMPLETE
1 SLEW:MODE FIXED
2 SLEW:MODE STEP
3 SLEW:MODE PULSE
4 SLEW:MODE LIST
width
SLEW rate
SLEW:T rate
VOLT:T level
SLEW:T rate
SLEW rate SLEW rate
SLEW:T
rate
SLEW rate
SLEW
[
3
]
SLEW
[
2
]
VOLT level